Modeling And Diagnostic Of Permanent Magnet Synchronous Machine Under Insulation Failure Condition

Authors : Bouchareb Chourouk . Nait Said Mohamed Said . Lahmer Fethi .

Abstract

One of the most frequent faults in PMSM stator is the turn-to-turn short-circuit fault. So, the aim of this paper is to present a dynamic model for PMSM with turn-to-turn short-circuit fault based on equivalent electric circuit model. Two simple and useful diagnostic techniques ESA an EPVA based on frequency analysis are applied to detect this kind of fault. The accuracy of diagnosis is based on adding the real waveform of back-EMF

Keywords

PMSM? inter-turn short circuit, modeling, ESA, EPVA

Electromagnetic Comparison Of 3-, 5- And 7-phases Permanent-magnet Synchronous Machines : Mild Hybrid Traction Application

Ouamara D. .  Dubas F .  Randi S-a. .  Benallal M. N. .  Espanet C. . 
pages 012-022.


Fuzzy Logic Based Vector Control Of Multi-phase Permanent Magnet Synchronous Motors

Mehedi F. .  Nezli L. .  Mahmoudi M.o. .  Taleb R. .  Boudana D. . 
pages 161-170.


Backstepping Speed Controller Design For A Multi-phase Permanent Magnet Synchronous Motor Drive

Mehedi F. .  Nezli L. .  Mahmoudi M.o. .  Taleb R. .  Boudjana D. . 
pages 269-278.


Power Maximization Control Of Small Wind System Using Permanent Magnet Synchronous Generator

Belakehal S. .  Benalla H. .  Bentounsi A. . 
pages 307-319.