Rеvuе des Energies Renouvelables
Volume 8, Numéro 2, Pages 73-80
2005-12-31
Authors : Benfarhat K. . Terki F. . Goutali I. .
One of the most delicate parts to size in a water pumping windmill is the pump rod. Indeed, frequent ruptures during the exploitation and experimentation of windmills shows that the determination of the real forces acting on the pump rod is quite difficult to evaluate. The calculation of these forces is traditionally achieved by taking as a maximal force the sum of the static loads. The calculation model used in this article takes into account the hydraulic pressure losses, inertia forces and the shock force caused by the water column on the piston. This will make it possible to better know the forces acting on the pump rod and therefore to perform better sizing.
Windmill - Pumping - Loads - Force - Pump rod.